09 96 53Elastomeric Coatings
Rhino Shield Ceramic Coating System
On stucco, concrete, masonry, cement board and metal.
Home/Architects and engineers
Architects and engineers
CSI guide specifications, performance requirements tied to a named method and report, and submittals keyed paragraph by paragraph to your section.



Guide specifications

09 96 53Elastomeric Coatings
On stucco, concrete, masonry, cement board and metal.

09 67 23Resinous Flooring
In solid color, flake and quartz systems.
Performance data
The values on the commercial data sheets and in the guide specifications. The full reports are bound in a test book for each system and go to any reviewer who asks.
| Property | Result | Method | Report |
|---|---|---|---|
| Slip resistance, wet | DCOF 0.51 with the specified silica; the guide specification minimum is 0.42 | ANSI A326.3 | AmCoat test report |
| Slip resistance, wet, heavy slip finish | DCOF 0.67 with 16 oz. 40 size silica per gallon in the color coat | ANSI A326.3 | AmCoat test report |
| Bond to concrete | 404 to 459 psi, with failure in the concrete | ASTM D4541 | AmCoat test reports |
| Abrasion resistance | 3.65 mg loss, CS-17 wheels, 1,000 cycles | ASTM D4060 | AmCoat test report |
| Hardness | 77 Shore D | ASTM D2240 | AmCoat test report |
| Impact resistance | 192 inch pounds, direct and reverse | ASTM D2794 | AmCoat test report |
| Flexibility | Pass | ASTM D522 | AmCoat test report |
| Hot tire pickup | 10 of 10 for imprint, adhesion and tread mark at 14 days | In house method | AmCoat test report |
| UV exposure, clear coat | Color change ΔE 0.13 after 1,000 hours of QUV | In house method | AmCoat test report |
| Property | Result | Method | Report |
|---|---|---|---|
| Adhesion | 533 psi to concrete; 567 psi to wood | ASTM D4541 | DRM Consulting |
| Elongation | 538% white base; 550% deep base, after 1,058 hours UVA QUV | Lab report | Future Labs |
| Tensile strength | 212 psi white base; 340 psi deep base | Lab report | Future Labs |
| Surface burning | Class A with APS; flame spread 5, smoke developed 0 | ASTM E84 | Commercial Testing Company |
| Salt fog | 500 hours, rating 10, no blisters | ASTM B117 | Q-Lab |
| Wind driven rain | Pass, no visible water leaks | ASTM D6904 | KTA-Tator |
| Fungal resistance | Resists fungal growth | ASTM D5590 | MicroStar Lab |
| Solar reflectance index | 105.3 matte white; 107.4 satin white; solar reflectance 0.837 and 0.852; thermal emittance 0.90 | ASTM E1980; C1549; C1371 | ACE Laboratories |
Rhino Shield results are for the white base unless another base is named. Floor Shield results are from AmCoat's own test reports, reproduced in the Floor Shield test book.
Submittals and test books
Each submittal opens with a transmittal that has blocks for AmCoat's release, the contractor's review and your action, a contents page keyed to the specification paragraphs, and a statement of compliance that walks every requirement with the evidence beside it.
The test books hold the full reports: Rhino Shield 25 pages from six independent laboratories, Floor Shield 21 pages.
Request the test books1 · Product Data
5 · Safety Data Sheets
2 · Samples
6 · Manufacturer's Instructions
3 · Qualification Data
7 · Sample Warranty
4 · Product Test Reports
8 · Maintenance Data
Technical support
Substrate questions, approved equal language, moisture limits, slip requirements by space. Ask before the section is issued, not after the bid.
Technical and specification support
Director of Product and Applications
Walls, floors or both. Tell us about it and we will tell you what fits.