Commercial, institutional, military and federal projects 850-424-6805 Residential projects
AmCoat Industrial, High Performance Coating Systems

Home/Architects and engineers

Architects and engineers

Built to be specified.

CSI guide specifications, performance requirements tied to a named method and report, and submittals keyed paragraph by paragraph to your section.

Rhino Shield DFC commercial product data sheet, page 1
Floor Shield-W commercial product data sheet, page 1
Section 09 96 53 guide specification, Part 2 performance requirements

Guide specifications

Two sections, ready for the project manual

Rhino Shield

09 96 53Elastomeric Coatings

Rhino Shield Ceramic Coating System

On stucco, concrete, masonry, cement board and metal.

Floor Shield

09 67 23Resinous Flooring

Floor Shield Polyaspartic Floor Coating System

In solid color, flake and quartz systems.

Three partCSI format with specifier notes and bracketed options
Named reportsPerformance requirements tied to the test reports
Matched tabsSubmittal articles that match the submittal tabs
Word and PDFEditable for the architect, PDF for review

Performance data

Every number names its method and its report

The values on the commercial data sheets and in the guide specifications. The full reports are bound in a test book for each system and go to any reviewer who asks.

PropertyResultMethodReport
Slip resistance, wetDCOF 0.51 with the specified silica; the guide specification minimum is 0.42ANSI A326.3AmCoat test report
Slip resistance, wet, heavy slip finishDCOF 0.67 with 16 oz. 40 size silica per gallon in the color coatANSI A326.3AmCoat test report
Bond to concrete404 to 459 psi, with failure in the concreteASTM D4541AmCoat test reports
Abrasion resistance3.65 mg loss, CS-17 wheels, 1,000 cyclesASTM D4060AmCoat test report
Hardness77 Shore DASTM D2240AmCoat test report
Impact resistance192 inch pounds, direct and reverseASTM D2794AmCoat test report
FlexibilityPassASTM D522AmCoat test report
Hot tire pickup10 of 10 for imprint, adhesion and tread mark at 14 daysIn house methodAmCoat test report
UV exposure, clear coatColor change ΔE 0.13 after 1,000 hours of QUVIn house methodAmCoat test report

Rhino Shield results are for the white base unless another base is named. Floor Shield results are from AmCoat's own test reports, reproduced in the Floor Shield test book.

Submittals and test books

One bound answer to each specification

Each submittal opens with a transmittal that has blocks for AmCoat's release, the contractor's review and your action, a contents page keyed to the specification paragraphs, and a statement of compliance that walks every requirement with the evidence beside it.

The test books hold the full reports: Rhino Shield 25 pages from six independent laboratories, Floor Shield 21 pages.

Request the test books

1 · Product Data

5 · Safety Data Sheets

2 · Samples

6 · Manufacturer's Instructions

3 · Qualification Data

7 · Sample Warranty

4 · Product Test Reports

8 · Maintenance Data

Technical support

Answers from the people who formulate the product

Substrate questions, approved equal language, moisture limits, slip requirements by space. Ask before the section is issued, not after the bid.

Technical and specification support

Mike Moore

Director of Product and Applications

Have a building in mind?

Walls, floors or both. Tell us about it and we will tell you what fits.

Start a project