Commercial, institutional, military and federal projects 850-424-6805 Residential projects
AmCoat Industrial, High Performance Coating Systems

Home/Owners

Owners and facility managers

Less downtime. Fewer repaints. Safer floors.

What Rhino Shield and Floor Shield change for the people who own, manage and maintain the building, and what to plan for before the work starts.

4 to 5 hoursTypical time until Floor Shield takes foot traffic
105.3 to 107.4Solar reflectance index of the white Rhino Shield finishes
Per projectWritten limited material warranty

Floors

Open again in hours, not days

Floor Shield coats go on hours apart and the floor typically takes foot traffic 4 to 5 hours after application. With zero VOC and low odor, the rest of the building can stay open.

  • Slip resistant finish: wet DCOF 0.51 with the specified silica
  • Hard, abrasion resistant surface that resists wear and staining and reduces floor care
  • Resists splashes and spills of commercial cleaning chemicals, pool water treatment products and hot tire pickup
  • UV resistant and non yellowing, so sunlit walkways and breezeways keep their color
Slip testing, and polyaspartic compared with epoxy

Return to service after the last coat

1 hourNext coat, earliest

4 to 5 hoursFoot traffic, typical

24 hoursVehicle traffic

Times at 70°F and 50% relative humidity. Lower temperature or humidity lengthens them.

Refurbished ramp with a slip resistant finish
Refurbished ramp with extra slip resistance
Glossy white floor in a food prep room
SkyChef prep room · JFK Airport
Floor in a craft bar
Chans Craft Bar · Destin, Florida

Walls

Built for sun, salt air and storms

Rhino Shield is a ceramic elastomeric coating system, not a paint. Here is what that means for an exterior wall.

105.3SRI, matte white

Reflects the sun's heat

The solar reflectance index measures how well a surface stays cool in direct sun; a standard white surface scores 100. The white Rhino Shield finishes score 105.3 matte and 107.4 satin, which keeps sunlit walls cooler. In an infrared field study, the Rhino Shield half of a test wall read 19.3°F cooler than the half in matching latex paint.

Infrared images and the Cool Colors chart

500 hSalt fog

Stands up to coastal exposure

500 hours of salt fog with no blisters, and a pass on wind driven rain testing with no visible water leaks.

538%Elongation

Moves with the building

The high build film stays flexible after 1,058 hours of UV exposure, so it moves with the wall and seals hairline cracks. It is breathable, so water vapor can escape.

Class ASurface burning

Fire rated as a system

Class A under ASTM E84 with APS primer: flame spread 5, smoke developed 0.

Before and after

A working bay, back in service

Bare, stained concrete in a car wash bay, then the same bay with a sealed, seamless floor.

BeforeCar wash bay before coating, bare stained concrete
Car wash bay · before
AfterCar wash bay after coating, glossy sealed floor
Car wash bay · after

Straight answers

Where each system fits, and what to plan for

No coating is right for every surface. These are the conditions we check before we recommend either system.

Floor Shield

Strong fit

  • Walkways, breezeways, stairs and landings
  • Restrooms, kitchens and dining areas
  • Hangars, fire stations and warehousing
  • Automotive service areas and animal housing
  • Medical and dental facilities

Plan for

  • Moisture testing of the slab before work starts; high vapor emission calls for the Moisture Vapor Barrier primer
  • Diamond grinding to profile on every job; old coatings and adhesives add time
  • Acrylic sealers, paints and stains come off first
  • Vehicle areas stay closed 24 hours

Rhino Shield

Strong fit

  • Exterior walls of commercial, institutional, multifamily and condominium buildings
  • Hotels, resorts and retail centers
  • Stucco, block, brick, concrete, cement board and metal
  • New construction and recoating existing walls

Plan for

  • Repairs and cleaning before coating
  • Overspray protection and site control when sprayed
  • No application below 40°F
  • Existing coatings pass an adhesion tape test first
  • Walls only; not for horizontal surfaces or walls with water pressure from behind

Warranty

A warranty written for your building

Every project gets a manufacturer's limited material warranty, completed for that building. The conditions are in writing before the work starts, not after a claim.

Coverage
Owner, project, system, area and batch numbers named on the form
Conditions
An approved applicator, the published instructions, and recorded moisture and adhesion readings
Remedy
Replacement material for the affected area
Claims
Written notice with photographs and access to inspect

Markets

Where owners use the systems

Holiday Inn entrance and porte cochere
Holiday Inn · Port Arthur, Texas

Hospitality and multifamily

Floors
Covered walkways, breezeways, stairs and landings
Walls
Stucco, concrete and fiber cement exteriors in salt air
Aerial view of the Destin High campus
Destin High · Destin, Florida

Education and public assembly

Floors
Restrooms, dining areas, atriums and corridors
Walls
Masonry and block buildings that take on water
Delmar Gardens building coated with Rhino Shield
Rhino Shield · Delmar Gardens

Healthcare and retail

Floors
Medical and dental facilities, retail stores, malls and restaurant kitchens
Walls
Envelopes where repainting disrupts patients and customers
Vehicle maintenance facility floor
Maintenance facility · State of Kentucky

Industrial, fleet and aviation

Floors
Fire stations, hangars, warehousing and service areas
Walls
Block and metal buildings, with Red Iron Oxide primer on steel

Have a building in mind?

Walls, floors or both. Tell us about it and we will tell you what fits.

Start a project